Home  | Legals | Sitemap | KIT

A New Test Facility to Investigate Film Cooling on a Non-Axisymmetric Contoured Turbine Endwall, Part II: Heat Transfer and Film Cooling Measurements

A New Test Facility to Investigate Film Cooling on a Non-Axisymmetric Contoured Turbine Endwall, Part II: Heat Transfer and Film Cooling Measurements
Chair:

ASME Turbo Expo 2015
Turbine Technical Conference and Exposition

links:Links_bearbeiten
Place:

Montreal, Canada

Author:

Bauer, H.-J.
Schulz, Achmed
Kneer, Johannes
Pütz, Franz

Time:

15.06.2015 - 19.06.2015

Source:

Paper No.: GT2015-42524

The present work is part of a comprehensive heat transfer and film-cooling study on a locally cooled non-axisymmetric contoured turbine endwall. A new test rig consisting of a linear cascade of three prismatic vanes at unity scale and exchangeable endwall has been established. The rig is operated in an open-loop configuration at a reduced main gas temperature of 425 K, an exit Mach number of 0.5, and an exit Reynolds number of 1.6×10^6. Air is used both as main gas and coolant; a realistic density ratio is achieved by cooling the coolant below freezing. In Part I [1] of the study aerodynamic measurements are presented. This paper concentrates on film-cooling of the contoured endwall with special emphasis on data acquisition and reduction for the application of the superposition principle of film cooling. First experimental results from thermographic measurements are discussed.